It can be processed according to the drawings and samples, receive oem orders, accept wholesale and customization. Provide a complete set of motor protection system solutions. Voltage Parameter:3kv Power(kW) Size:2500kw Body Size:Customized
Product Overview
RZMV series medium voltage solid state soft starter device is the latest generation of perfect, reliable and convenient maintenance of high-tech products. It is mainly used for starting and stopping control and protection of squirrel cage asynchronous synchronous starter.The device adopts a number of thyristor series and connected, can meet the current and voltage requirements .
They are widely used in rated voltage 3000-10000V power ,building materials ,chemical, metallurgy steel , paper making and other industries .it is the ideal medium voltage motor starting and protection equipment for mercury water,blower compressor, grinder mixer,Pitty machine and other mechanical equipment.
Device Introduction
Medium voltage soft starter is a new intelligent motor starter, it is suitable for squirrel-cage asynchronous and synchronous motors. It is a Integrated motor terminal control equipment of starter, display, Protection, data collection . Users can achieve more complex control functions by using fewer components. The medium voltage soft starter controls the input voltage through the conduction Angle between the control items in order to change the voltage value at he starter end of a motor, that is, control the starting torque and starting current of the motor to realize the motor soft start control. Medium voltage soft starter can accelerate smoothly according to the set starting parameters, thus reducing the electrical and mechanical impact on the power grid, motor and equipment. When the motor reaches the rated speed, the bypass contactor is switched on automatically. The medium voltage soft starter continues to monitor the motor after starting and provides various fault protection.
Technical Characteristics
Fiber trigger components:Use strong trigger pulse circuit, to ensure the trigger consistency and reliability, using fiber optic trigger to Realize high and low voltage isolation .
Cabinet structure adopts KYN28 high voltage switch cabinet body, the main structure adopts 2mm aluminum-zinc steel plate compound folding process, cabinet door adopts 2mm cold rolled steel plate compound folding process, cabinet door adopts electrostatic spraying process, the characteristics of im act resistance corrosion resistance and beautiful a earance. The rotection level is IP40.
Functional Features
A variety of starting ways;
Basic Parameters Sheet
The Load Type
|
Three-phase medium voltage squirrel cage asynchronous motor, synchronous motor
|
Rated Voltage
|
3000---10000VAC
|
Working Frequency
|
50Hz
|
Phase Sequence
|
Allowed to work in any phase sequence (phase sequence detection can be set by parameter)
|
Main Loop Composition
|
12SCRS、18SCRS、30SCRS(Depending on the model and rated voltage)
|
Bypass Contactor
|
Contactor with direct starting capacity |
Control Power
|
AC220V±15% |
Transient voltage overload protection
|
dv/dt Absorption of protection
|
Starter per hour
|
No more than 3 starting times per hour
|
Environmental conditions
|
:-10℃ -±50℃
relative humidity:5% -95% Without condensation
Capacity reduction is required when the altitude exceeds 1500 meters
|
Open-phase protection | Disconnect any phase of the main power supply during startup or operation |
Working overcurrent protection | Run overcurrent protection Settings :20~500% |
Phase current imbalance protection | Phase current imbalance protection:0~100% |
Overload protection | Overload protection level :10A、10、15、20、25、30 |
Underload protection | Overload protection level :10A、10、15、20、25、30 |
Overtime of Starting | limitation of Starting time :0~120S |
Phase Sequence Protection | Allows to work in any phase sequence (can be set by parameter) |
Ground protection | Protection when grounding current is bigger than the set value |
Communication Description
Communication Agreement | Modbus RTU |
Communication Connector | RS485 |
Network Connection | Each RZMV can communicate with 30 RZMV devices on the network |
Function | Through the communication interface, you can observe the running status and program |
Operation Interface
LCD display (optional contact screen)
|
LCD liquid crystal display (optional touch screen display) |
Language | Chinese , English |
Keyboard | 6 touch film buttons |
Master Power Supply |
Display three-phase main voltage
|
Three Phase Current
|
Display three-phase main loop current
|
Error Record
|
Record the latest15 faults
|
Starting Times
|
Record the starting times of the device
|
Technical Parameter
Voltage Parameter
|
Power(kW) Size |
Size
|
Rated Current (A)
|
W (mm) |
H (mm) |
D (mm) |
3KV |
400 | RZMV-400-3 | 100 |
1000 |
2300 | 1500 |
630 |
RZMV-630-3 |
150 | 2300 | 1500 | ||
1600 |
RZMV-1600-3 |
400 | 1150 | 2300 | 1500 | |
2500 |
RZMV-2500-3 |
600 |
Customized |
Excellent quality products are the the foundation for us to stand out in the industry competition.we strictly control the quality of all products and each component with the most advanced international quality management technology
Regularly organize professional training for quality management personnel, do our best to ensureperfect quality.
For many years, we uphold the business principle that“quality is our life, reputation is the basis, strictly implement ISO9001Management system of international quality system